701 lines
21 KiB
YAML
701 lines
21 KiB
YAML
testActions:
|
||
prereq_147: &prereq_147
|
||
id: prereq_147
|
||
document: '<p>在热停堆工况(热功率稳定),平均温度最大允许变化<0.2℃;若KIC中显示的三个环路平均温度变化AT>0.2℃,则采取数据滑动平均方式,期间确保三个环路平均温度的滑动平均值最大最小值之差<0.2℃、测量时间大于滑动周期。</p>'
|
||
mode: manual
|
||
dataFields:
|
||
- tableRef: '#/tables/manualConfirm'
|
||
fields: [confirm_147]
|
||
prereq_150: &prereq_150
|
||
id: prereq_150
|
||
document: '<p>三个蒸发器处于稳定状态,压力一致。</p>'
|
||
mode: manual
|
||
dataFields:
|
||
- tableRef: '#/tables/manualConfirm'
|
||
fields: [confirm_150]
|
||
prereq_43: &prereq_43
|
||
id: prereq_43
|
||
document: '<p>蒸汽发生器水位稳定。</p>'
|
||
mode: manual
|
||
dataFields:
|
||
- tableRef: '#/tables/manualConfirm'
|
||
fields: [confirm_43]
|
||
prereq_75: &prereq_75
|
||
id: prereq_75
|
||
document: '<p>RCV的一个下泄孔板投入运行;确保测量期间无下泄孔板相关操作,一回路温度保持稳定,测量结果若超差需要分析下泄流量影响。</p>'
|
||
mode: manual
|
||
dataFields:
|
||
- tableRef: '#/tables/manualConfirm'
|
||
fields: [confirm_75]
|
||
prereq_92: &prereq_92
|
||
id: prereq_92
|
||
document: '<p>其它模式/工况下需进行相应的独立风险分析。</p>'
|
||
mode: manual
|
||
dataFields:
|
||
- tableRef: '#/tables/manualConfirm'
|
||
fields: [confirm_92]
|
||
pre_153: &pre_153
|
||
id: pre_153
|
||
document: '<p>本程序适用于热停堆(热功率稳定)工况下执行RCP63程序,统一进行Sensor Check部分使用。</p>'
|
||
mode: manual
|
||
dataFields:
|
||
- tableRef: '#/tables/manualConfirm'
|
||
fields: [confirm_153]
|
||
pre_136: &pre_136
|
||
id: pre_136
|
||
document: '<p>执行前确认KIC中一回路三个环路平均温度变化量不超过0.2℃。</p>'
|
||
mode: auto
|
||
functionType: DATA_ACQUISITION_WITH_VALIDATION
|
||
functionParameters:
|
||
- RCP614KM
|
||
- RCP618KM
|
||
- RCP622KM
|
||
dataFields:
|
||
- tableRef: '#/tables/temperatureCheckTable'
|
||
fields: [loop1TempVariation, loop2TempVariation, loop3TempVariation]
|
||
pre_137: &pre_137
|
||
id: pre_137
|
||
document: '<p>若三环路平均温度变化超过0.2℃,记录滑动周期、各环路滑动平均最大最小值之差及最短数据测量时间,确认均满足≤0.2℃且测量时间>滑动周期。</p>'
|
||
mode: auto
|
||
functionType: DATA_ACQUISITION_WITH_VALIDATION
|
||
functionParameters:
|
||
- RCP614KM
|
||
- RCP618KM
|
||
- RCP622KM
|
||
- RCP612KM
|
||
- RCP616KM
|
||
- RCP620KM
|
||
- RCP613KM
|
||
- RCP617KM
|
||
- RCP621KM
|
||
- RCP611KM
|
||
- RCP615KM
|
||
- RCP619KM
|
||
dataFields:
|
||
- tableRef: '#/tables/temperatureCheckTable'
|
||
fields: [loop1TempVariation, loop2TempVariation, loop3TempVariation]
|
||
pre_138: &pre_138
|
||
id: pre_138
|
||
document: '<p>确认 RPR、RPN上无相关的试验检修工作。</p>'
|
||
mode: manual
|
||
dataFields:
|
||
- tableRef: '#/tables/manualConfirm'
|
||
fields: [confirm_138]
|
||
pre_139: &pre_139
|
||
id: pre_139
|
||
document: '<p>按附表1检查相关模拟量指示并记录,确认结果满意。</p>'
|
||
mode: auto
|
||
functionType: DATA_ACQUISITION
|
||
functionParameters:
|
||
- RCP614KM
|
||
- RCP618KM
|
||
- RCP622KM
|
||
dataFields:
|
||
- tableRef: '#/tables/alarmCheckTable'
|
||
cells:
|
||
- row: RCP614KM
|
||
column: preInspectionStatus
|
||
- row: RCP618KM
|
||
column: preInspectionStatus
|
||
- row: RCP622KM
|
||
column: preInspectionStatus
|
||
pre_140: &pre_140
|
||
id: pre_140
|
||
document: '<p>试验前根据附表1报警清单检查报警,确认无异常报警,方可进行后续检查工作。</p>'
|
||
mode: auto
|
||
functionType: DATA_ACQUISITION
|
||
functionParameters:
|
||
- RCP455AA
|
||
- RPAB138AA
|
||
- RPAB167AA
|
||
- RPAB171AA
|
||
dataFields:
|
||
- tableRef: '#/tables/alarmCheckTable'
|
||
cells:
|
||
- row: RCP455AA
|
||
column: preInspectionStatus
|
||
- row: RPAB138AA
|
||
column: preInspectionStatus
|
||
- row: RPAB167AA
|
||
column: preInspectionStatus
|
||
- row: RPAB171AA
|
||
column: preInspectionStatus
|
||
x5KicReadingsPreCheck: &x5KicReadingsPreCheck
|
||
id: x5KicReadingsPreCheck
|
||
document: '<p>采集X5端子排拆前KIC指示值。</p>'
|
||
mode: auto
|
||
functionType: DATA_ACQUISITION
|
||
functionParameters:
|
||
- RCP030MT
|
||
- RCP033MT
|
||
dataFields:
|
||
- tableRef: '#/tables/kicReadingsTable'
|
||
cells:
|
||
- row: RCP030MT
|
||
column: preInspectionValue
|
||
- row: RCP033MT
|
||
column: preInspectionValue
|
||
x5KicReadingsPostCheck: &x5KicReadingsPostCheck
|
||
id: x5KicReadingsPostCheck
|
||
document: '<p>采集X5端子排恢复后KIC指示值。</p>'
|
||
mode: auto
|
||
functionType: DATA_ACQUISITION
|
||
functionParameters:
|
||
- RCP030MT
|
||
- RCP033MT
|
||
dataFields:
|
||
- tableRef: '#/tables/kicReadingsTable'
|
||
cells:
|
||
- row: RCP030MT
|
||
column: postInspectionValue
|
||
- row: RCP033MT
|
||
column: postInspectionValue
|
||
rcp030mtResistance: &rcp030mtResistance
|
||
id: rcp030mtResistance
|
||
mode: auto
|
||
functionType: RESISTANCE_4WIRE
|
||
channel: input1
|
||
functionParameters:
|
||
document: '<p><strong>测量位置:</strong>KCSO13AR/EB911/X5</p><p><strong>测量项目:</strong>R1/2, R1/3, R1/4, R2/3, R2/4, R3/4, R/4wires</p>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP030MT
|
||
column: r12
|
||
- row: RCP030MT
|
||
column: r13
|
||
- row: RCP030MT
|
||
column: r14
|
||
- row: RCP030MT
|
||
column: r23
|
||
- row: RCP030MT
|
||
column: r24
|
||
- row: RCP030MT
|
||
column: r34
|
||
- row: RCP030MT
|
||
column: r4wires
|
||
uploadStrategy: inherit
|
||
rcp030mtInsulation: &rcp030mtInsulation
|
||
id: rcp030mtInsulation
|
||
mode: auto
|
||
functionType: INSULATION
|
||
channel: input1
|
||
functionParameters:
|
||
testVoltage: 50
|
||
testTime: 20
|
||
dischargeTime: 5
|
||
document: '<p><strong>测量位置:</strong>KCSO13AR/EB911/X5</p><p><strong>注意事项:</strong></p><ul><li>测试电压50V</li><li>测试时间不小于20秒</li><li>测量后探头对地放电</li></ul>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP030MT
|
||
column: insulation
|
||
uploadStrategy: inherit
|
||
rcp033mtResistance: &rcp033mtResistance
|
||
id: rcp033mtResistance
|
||
mode: auto
|
||
functionType: RESISTANCE_4WIRE
|
||
channel: input1
|
||
functionParameters:
|
||
document: '<p><strong>测量位置:</strong>KCSO13AR/EB911/X5</p><p><strong>测量项目:</strong>R1/2, R1/3, R1/4, R2/3, R2/4, R3/4, R/4wires</p>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP033MT
|
||
column: r12
|
||
- row: RCP033MT
|
||
column: r13
|
||
- row: RCP033MT
|
||
column: r14
|
||
- row: RCP033MT
|
||
column: r23
|
||
- row: RCP033MT
|
||
column: r24
|
||
- row: RCP033MT
|
||
column: r34
|
||
- row: RCP033MT
|
||
column: r4wires
|
||
uploadStrategy: inherit
|
||
rcp033mtInsulation: &rcp033mtInsulation
|
||
id: rcp033mtInsulation
|
||
mode: auto
|
||
functionType: INSULATION
|
||
channel: input1
|
||
functionParameters:
|
||
testVoltage: 50
|
||
testTime: 20
|
||
dischargeTime: 5
|
||
document: '<p><strong>测量位置:</strong>KCSO13AR/EB911/X5</p><p><strong>注意事项:</strong></p><ul><li>测试电压50V</li><li>测试时间不小于20秒</li><li>测量后探头对地放电</li><li>复归保险FB059 F11和F12</li></ul>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP033MT
|
||
column: insulation
|
||
uploadStrategy: inherit
|
||
rcp031mtResistance: &rcp031mtResistance
|
||
id: rcp031mtResistance
|
||
mode: auto
|
||
functionType: RESISTANCE_4WIRE
|
||
channel: input1
|
||
functionParameters:
|
||
document: '<p><strong>测量位置:</strong>KCS013AR/EB911/X6</p><p><strong>测量项目:</strong>R1/2, R1/3, R1/4, R2/3, R2/4, R3/4, R/4wires</p>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP031MT
|
||
column: r12
|
||
- row: RCP031MT
|
||
column: r13
|
||
- row: RCP031MT
|
||
column: r14
|
||
- row: RCP031MT
|
||
column: r23
|
||
- row: RCP031MT
|
||
column: r24
|
||
- row: RCP031MT
|
||
column: r34
|
||
- row: RCP031MT
|
||
column: r4wires
|
||
uploadStrategy: inherit
|
||
rcp031mtInsulation: &rcp031mtInsulation
|
||
id: rcp031mtInsulation
|
||
mode: auto
|
||
functionType: INSULATION
|
||
channel: input1
|
||
functionParameters:
|
||
testVoltage: 50
|
||
testTime: 20
|
||
dischargeTime: 5
|
||
document: '<p><strong>测量位置:</strong>KCS013AR/EB911/X6</p><p><strong>注意事项:</strong></p><ul><li>测试电压50V</li><li>测试时间不小于20秒</li><li>测量后探头对地放电</li></ul>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP031MT
|
||
column: insulation
|
||
uploadStrategy: inherit
|
||
rcp034mtResistance: &rcp034mtResistance
|
||
id: rcp034mtResistance
|
||
mode: auto
|
||
functionType: RESISTANCE_4WIRE
|
||
channel: input1
|
||
functionParameters:
|
||
document: '<p><strong>测量位置:</strong>KCS013AR/EB911/X6</p><p><strong>测量项目:</strong>R1/2, R1/3, R1/4, R2/3, R2/4, R3/4, R/4wires</p>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP034MT
|
||
column: r12
|
||
- row: RCP034MT
|
||
column: r13
|
||
- row: RCP034MT
|
||
column: r14
|
||
- row: RCP034MT
|
||
column: r23
|
||
- row: RCP034MT
|
||
column: r24
|
||
- row: RCP034MT
|
||
column: r34
|
||
- row: RCP034MT
|
||
column: r4wires
|
||
uploadStrategy: inherit
|
||
rcp034mtInsulation: &rcp034mtInsulation
|
||
id: rcp034mtInsulation
|
||
mode: auto
|
||
functionType: INSULATION
|
||
channel: input1
|
||
functionParameters:
|
||
testVoltage: 50
|
||
testTime: 20
|
||
dischargeTime: 5
|
||
document: '<p><strong>测量位置:</strong>KCS013AR/EB911/X6</p><p><strong>注意事项:</strong></p><ul><li>测试电压50V</li><li>测试时间不小于20秒</li><li>测量后探头对地放电</li></ul>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP034MT
|
||
column: insulation
|
||
uploadStrategy: inherit
|
||
rcp043mtResistance: &rcp043mtResistance
|
||
id: rcp043mtResistance
|
||
mode: auto
|
||
functionType: RESISTANCE_3WIRE
|
||
channel: input1
|
||
functionParameters:
|
||
document: '<p><strong>测量位置:</strong>KCSO13AR/EB902/X1</p><p><strong>测量项目:</strong>R2/3, R2/4, R3/4</p><p><strong>注意:</strong>3线制传感器</p>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP043MT
|
||
column: r23
|
||
- row: RCP043MT
|
||
column: r24
|
||
- row: RCP043MT
|
||
column: r34
|
||
uploadStrategy: inherit
|
||
rcp043mtInsulation: &rcp043mtInsulation
|
||
id: rcp043mtInsulation
|
||
mode: auto
|
||
functionType: INSULATION
|
||
channel: input1
|
||
functionParameters:
|
||
testVoltage: 50
|
||
testTime: 20
|
||
dischargeTime: 5
|
||
document: '<p><strong>测量位置:</strong>KCSO13AR/EB902/X1</p><p><strong>注意事项:</strong></p><ul><li>测试电压50V</li><li>测试时间不小于20秒</li><li>测量后探头对地放电</li></ul>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP043MT
|
||
column: insulation
|
||
uploadStrategy: inherit
|
||
rcp044mtResistance: &rcp044mtResistance
|
||
id: rcp044mtResistance
|
||
mode: auto
|
||
functionType: RESISTANCE_3WIRE
|
||
channel: input1
|
||
functionParameters:
|
||
document: '<p><strong>测量位置:</strong>KCSO13AR/EB902/X1</p><p><strong>测量项目:</strong>R2/3, R2/4, R3/4</p><p><strong>注意:</strong>3线制传感器</p>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP044MT
|
||
column: r23
|
||
- row: RCP044MT
|
||
column: r24
|
||
- row: RCP044MT
|
||
column: r34
|
||
uploadStrategy: inherit
|
||
rcp044mtInsulation: &rcp044mtInsulation
|
||
id: rcp044mtInsulation
|
||
mode: auto
|
||
functionType: INSULATION
|
||
channel: input1
|
||
functionParameters:
|
||
testVoltage: 50
|
||
testTime: 20
|
||
dischargeTime: 5
|
||
document: '<p><strong>测量位置:</strong>KCSO13AR/EB902/X1</p><p><strong>注意事项:</strong></p><ul><li>测试电压50V</li><li>测试时间不小于20秒</li><li>测量后探头对地放电</li><li>复归保险FB005 F11和F12</li><li>请主控确认报警消除</li></ul>'
|
||
dataFields:
|
||
- tableRef: '#/tables/resistanceMeasurementTable'
|
||
cells:
|
||
- row: RCP044MT
|
||
column: insulation
|
||
uploadStrategy: inherit
|
||
testActivityGroups:
|
||
prerequisites: &prerequisites
|
||
id: prerequisites
|
||
name: 3.0先决条件
|
||
actions:
|
||
- *prereq_147
|
||
- *prereq_150
|
||
- *prereq_43
|
||
- *prereq_75
|
||
- *prereq_92
|
||
preInspectionChecks: &preInspectionChecks
|
||
id: preInspectionChecks
|
||
name: 5.1试验前状态说明和检查
|
||
tableRefs:
|
||
- '#/tables/temperatureCheckTable'
|
||
- '#/tables/alarmCheckTable'
|
||
actions:
|
||
- *pre_153
|
||
- *pre_136
|
||
- *pre_137
|
||
- *pre_138
|
||
- *pre_139
|
||
- *pre_140
|
||
protectionIGroup: &protectionIGroup
|
||
id: protectionIGroup
|
||
name: 5.2保护Ⅰ组传感器及线缆绝缘及电阻检查
|
||
tableRefs:
|
||
- '#/tables/kicReadingsTable'
|
||
- '#/tables/resistanceMeasurementTable'
|
||
actions:
|
||
- *x5KicReadingsPreCheck
|
||
- *rcp030mtResistance
|
||
- *rcp030mtInsulation
|
||
- *rcp033mtResistance
|
||
- *rcp033mtInsulation
|
||
- *x5KicReadingsPostCheck
|
||
testTaskGroups:
|
||
prerequisitesTask: &prerequisitesTask
|
||
id: prerequisitesTask
|
||
name: 3.0先决条件
|
||
stages:
|
||
- *prerequisites
|
||
preInspectionTask: &preInspectionTask
|
||
id: preInspectionTask
|
||
name: 5.1试验前状态说明和检查
|
||
stages:
|
||
- *preInspectionChecks
|
||
protectionITask: &protectionITask
|
||
id: protectionITask
|
||
name: 5.2保护Ⅰ组传感器及线缆绝缘及电阻检查
|
||
stages:
|
||
- *protectionIGroup
|
||
resultDisplays:
|
||
finalResultDisplay: &finalResultDisplay
|
||
id: finalResultDisplay
|
||
name: 实验结果汇总
|
||
document: '<p>显示本次实验的所有测量数据和检查结果</p>'
|
||
tableRefs:
|
||
- '#/tables/resistanceMeasurementTable'
|
||
- '#/tables/temperatureCheckTable'
|
||
- '#/tables/alarmCheckTable'
|
||
- '#/tables/kicReadingsTable'
|
||
procedure:
|
||
id: SIMPLE63
|
||
name: 范例 一回路温度传感器绝缘和连续性检查 TP RCP63
|
||
version: SIMPLE
|
||
activitySequence:
|
||
- *prerequisitesTask
|
||
- *preInspectionTask
|
||
- *protectionITask
|
||
- *finalResultDisplay
|
||
tables:
|
||
kicReadingsTable:
|
||
id: kicReadingsTable
|
||
name: KIC指示读数表
|
||
description: 检验前后的KIC指示读数
|
||
tableType: grid
|
||
isShared: true
|
||
uploadStrategy: onComplete
|
||
columnHeaders:
|
||
- id: preInspectionValue
|
||
name: 拆前数据
|
||
type: numeric
|
||
isRequired: true
|
||
unit: '℃'
|
||
- id: postInspectionValue
|
||
name: 拆后数据
|
||
type: numeric
|
||
isRequired: true
|
||
unit: '℃'
|
||
rowHeaders:
|
||
- id: RCP030MT
|
||
name: RCP030MT
|
||
- id: RCP033MT
|
||
name: RCP033MT
|
||
- id: RCP031MT
|
||
name: RCP031MT
|
||
- id: RCP034MT
|
||
name: RCP034MT
|
||
- id: RCP043MT
|
||
name: RCP043MT
|
||
- id: RCP044MT
|
||
name: RCP044MT
|
||
alarmCheckTable:
|
||
id: alarmCheckTable
|
||
name: 试验前后报警检查记录表
|
||
description: 依据TP RCP63的报警检查记录结构
|
||
tableType: grid
|
||
isShared: true
|
||
uploadStrategy: onComplete
|
||
columnHeaders:
|
||
- id: signal
|
||
name: 信号
|
||
type: text
|
||
isRequired: false
|
||
- id: description
|
||
name: 描述
|
||
type: text
|
||
isRequired: false
|
||
- id: location
|
||
name: 位置
|
||
type: text
|
||
isRequired: false
|
||
- id: normalState
|
||
name: 正常状态
|
||
type: text
|
||
isRequired: false
|
||
- id: eventTime
|
||
name: 出现时间
|
||
type: text
|
||
isRequired: false
|
||
- id: preInspectionStatus
|
||
name: 拆前状态
|
||
type: text
|
||
isRequired: true
|
||
- id: preInspectionStatusB
|
||
name: 拆前B列
|
||
type: text
|
||
isRequired: false
|
||
- id: postInspectionStatus
|
||
name: 拆后状态
|
||
type: text
|
||
isRequired: true
|
||
- id: postInspectionStatusB
|
||
name: 拆后B列
|
||
type: text
|
||
isRequired: false
|
||
rowHeaders:
|
||
- id: RCP455AA
|
||
name: RCP455AA
|
||
- id: RPAB138AA
|
||
name: RPA/B138AA
|
||
- id: RPAB167AA
|
||
name: RPA/B167AA
|
||
- id: RPAB171AA
|
||
name: RPA/B171AA
|
||
- id: RPA_B079AA
|
||
name: RPA/B079AA
|
||
- id: RPA_B039LA
|
||
name: RPA/B039LA
|
||
- id: RCP614KM
|
||
name: RCP614KM
|
||
- id: RCP618KM
|
||
name: RCP618KM
|
||
- id: RCP622KM
|
||
name: RCP622KM
|
||
manualConfirm:
|
||
id: manualConfirm
|
||
name: 人工确认
|
||
tableType: form
|
||
uploadStrategy: immediate
|
||
layoutConfig:
|
||
totalColumns: 12
|
||
fields:
|
||
- id: confirm_147
|
||
name: 确认 147
|
||
type: boolean
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
- id: confirm_150
|
||
name: 确认 150
|
||
type: boolean
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
- id: confirm_43
|
||
name: 确认 43
|
||
type: boolean
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
- id: confirm_75
|
||
name: 确认 75
|
||
type: boolean
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
- id: confirm_92
|
||
name: 确认 92
|
||
type: boolean
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
- id: confirm_153
|
||
name: 确认 153
|
||
type: boolean
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
- id: confirm_138
|
||
name: 确认 138
|
||
type: boolean
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
- id: confirm_142
|
||
name: 确认 142
|
||
type: boolean
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
resistanceMeasurementTable:
|
||
id: resistanceMeasurementTable
|
||
name: 电阻测量表
|
||
description: 传感器的电阻和绝缘测量数据
|
||
tableType: grid
|
||
uploadStrategy: onComplete
|
||
columnHeaders:
|
||
- id: r12
|
||
name: R1/2
|
||
type: numeric
|
||
isRequired: false
|
||
unit: Ω
|
||
- id: r13
|
||
name: R1/3
|
||
type: numeric
|
||
isRequired: false
|
||
unit: Ω
|
||
- id: r14
|
||
name: R1/4
|
||
type: numeric
|
||
isRequired: false
|
||
unit: Ω
|
||
- id: r23
|
||
name: R2/3
|
||
type: numeric
|
||
isRequired: true
|
||
unit: Ω
|
||
- id: r24
|
||
name: R2/4
|
||
type: numeric
|
||
isRequired: true
|
||
unit: Ω
|
||
- id: r34
|
||
name: R3/4
|
||
type: numeric
|
||
isRequired: true
|
||
unit: Ω
|
||
- id: r4wires
|
||
name: R/4wires
|
||
type: numeric
|
||
isRequired: false
|
||
unit: Ω
|
||
- id: insulation
|
||
name: Insulation
|
||
type: numeric
|
||
isRequired: true
|
||
unit: MΩ
|
||
rowHeaders:
|
||
- id: RCP030MT
|
||
name: RCP030MT
|
||
- id: RCP033MT
|
||
name: RCP033MT
|
||
- id: RCP031MT
|
||
name: RCP031MT
|
||
- id: RCP034MT
|
||
name: RCP034MT
|
||
- id: RCP043MT
|
||
name: RCP043MT
|
||
- id: RCP044MT
|
||
name: RCP044MT
|
||
temperatureCheckTable:
|
||
id: temperatureCheckTable
|
||
name: 环路温度检查表
|
||
description: 环路平均温度变化量检查
|
||
tableType: form
|
||
uploadStrategy: onComplete
|
||
layoutConfig:
|
||
totalColumns: 12
|
||
fields:
|
||
- id: loop1TempVariation
|
||
name: 一环路平均温度变化量
|
||
type: numeric
|
||
isRequired: true
|
||
unit: '℃'
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
order: 1
|
||
- id: loop2TempVariation
|
||
name: 二环路平均温度变化量
|
||
type: numeric
|
||
isRequired: true
|
||
unit: '℃'
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
order: 2
|
||
- id: loop3TempVariation
|
||
name: 三环路平均温度变化量
|
||
type: numeric
|
||
isRequired: true
|
||
unit: '℃'
|
||
layoutConfig:
|
||
labelSpan: 4
|
||
valueSpan: 8
|
||
order: 3
|